BZWFN - F8AM3430 CINEREX DEVELOPER SYSTEMS CLEANER PART-A 5-GALLONS

  • MSDS: BZWFN
  • Manufacturer: BAYER CORP AGFA DIV
  • Product Name: F8AM3430 CINEREX DEVELOPER SYSTEMS CLEANER PART-A 5-GALLONS
  • National Stock Number: 6750-00F049573
Product Identification

Product ID:F8AM3430 CINEREX DEVELOPER SYSTEMS CLEANER PART-A 5-GALLONS
MSDS Date:11/01/1990
FSC:6750
NIIN:00F049573
Kit Part:Y
MSDS Number: BZWFN

Responsible Party
BAYER CORP AGFA DIV
100 CHALLENGER RD
RIDGEFIELD PARK, NJ 07660-5000
US

Emergency Phone: 212-971-0260/201-440-2500

Info Phone: 201-440-2500/212-971-0260

Cage: EO426

Contractor
HELION INDUSTRIES INC
BELLEVILLE, NJ 07109 US

Telephone: 800-327-3456

Cage: 0AP29

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 50-60%


SULFURIC ACID (CONFIRMED HUMAN CARCINOGEN BY IARC - GROUP

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 30-40%

OSHA PEL 1 MG/CUM

ACGIH TLV: 1 MG/CUM=IC

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYES/SKIN: MAY CAUSE SEVERE IRRITATION
& BURNING. INHALATION: MIST MAY CAUSE RESPIRATORY IRRITATION.
INGESTION: MAY CAUSE SEVERE IRRITATION/BURNING OF MUCOUS
MEMBRANES/DIGESTIVE TRACT.
Explanation of Carcinogenicity:SEE INGREDIENTS.
Effects of Overexposure:IRRITATION & BURNING.

First Aid

First Aid:EYES/SKIN: IMMEDIATELY FLUSH W/PLENTY OF RUNNING WATER FOR 15
MINS. INHALATION: REMOVE TO FRESH AIR. OBTAIN MEDICAL ATTENTION IN
ALL CASES.

Fire Fighting

Flash Point:NON-COMBUSTIBLE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:ANY APPLICABLE TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:EVACUATE PERSONNEL TO A SAFE AREA. KEEP
PERSONNEL REMOVED & UPWIND OF FIRE. WEAR A SCBA.
Unusual Fire/Explosion Hazard:WHEN HEATED TO DECOMPOSITION, EMISSION OF
TOXIC FUMES OF SULFUR OXIDES IS POSSIBLE.

Accidental Release

Spill Release Procedures:WEAR APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT
DURING CLEANUP. DIKE. PREVENT LIQUID FROM ENTERING SEWERS,
WATERWAYS/LOW AREAS. SOAK UP W/SAWDUST, SAND, OIL DRY/OTHER
ABSORBENT MATERIAL. MAY BE NEUTRAL IZED.
Neutralizing Agent:POWDERED SODIUM CARBONATES.

Handling

Handling and Storage Precautions:STORE IN WELL VENTILATED AREA. KEEP
CONTAINER TIGHTLY CLOSED. DON'T STORE W/INCOMPATIBLE MATERIALS.
AVOID USE OF PRODUCT IN UNVENTILATED AREAS.
Other Precautions:DON'T STORE/CONSUME FOOD, DRINK/TOBACCO IN AREA WHERE
THEY MAY BECOME CONTAMINATED W/THIS MATERIAL.

Exposure Controls

Respiratory Protection:NONE NEEDED W/WORKING MIXTURES & NORMAL ROOM
VENTILATION.
Ventilation:ROOM VENTILATION IS SUFFICIENT.
Protective Gloves:CHEMICAL
Eye Protection:CHEMICAL SAFETY GOGGLES & FACE SHIELD
Other Protective Equipment:APRONS & BOOTS
Work Hygienic Practices:REMOVE CONTAMINATED CLOTHING.
Supplemental Safety and Health
PERCENT VOLATILE BY WEIGHT: 50-60%/WT. WASTE CONT'D: DISCHARGE TO SEWER
REQUIRES APPROVAL OF PERMITTING AUTHORITY & MAY REQUIRE
PRETREATMENT. DISPOSE OF IAW/FEDERAL, STATE & LOCAL REGULATIONS.
CORROSI VE MATERIAL UN1832. PRODUCT IS OBSOLETEPER SUSAN BORA.

Chemical Properties

Boiling Pt:B.P. Text:>212F
Spec Gravity:1.2
pH:<1
Evaporation Rate & Reference:(WATER = 1): <1
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR & COLORLESS W/NO ODOR.
Percent Volatiles by Volume:(SUPP)

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS & OXIDIZERS.
Hazardous Decomposition Products:CO2, CO, OXIDES OF SULFUR.

Disposal

Waste Disposal Methods:RECOVER NONUSABLE FREE LIQUID &/CONTAMINATED
WATER & DISPOSE OF IN APPROVED & PERMITTED TREATMENT SYSTEM. REMOVE
NONUSABLE SOLID MATERIAL &/CONTAMINATED SOIL FOR DISPOSAL IN
APPROVED & PERMITTED LANDF ILL. (SEE SUPP)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their